2000 Watt Off Grid Solar Inverter Charger, 24V/48V
24-volt/48-volt off-grid solar inverter/ inverter charger is 2000 watt (3000VA) power, pure sine wave output, available for sensitive load. It is designed with AC priority by default, when AC input is present, the battery will be charged first, and the inverter will transfer the input AC to power the load.
Features
- Pure sine wave output for compatibility with loads of different types
- Inverter has a mode of charging the battery from the AC supply with a charging capability of 0-30A
- Visualization of the operation status of the equipment through a digital LCD
- Automatically transfer between battery and line modes
- Pure sine wave output (THD < 3%) for a wide range of applications and harsh environment
- A wide range of input voltage, accurate output and all automatic voltage stabilization
- Overall protection functions (battery overvoltage protection, battery under voltage protection, overload protection, short circuit protection, and over-temperature protection)
Parameter List
Model | ATO-OGI-2000 | ||||||
Rated capacity | 3000VA | ||||||
Rated power load | 2000W | ||||||
Size | 620*270*220mm | ||||||
Net weight | 20kg | ||||||
Input | DC input | DC 21-30V (24V)/ DC 42-60V (48V) | |||||
AC input | 110V/ 120V/ 220V/ 230V/ 240V AC (Same as the output voltage) | ||||||
Frequency | 50Hz/ 60Hz±5% (Auto) | ||||||
Output | Voltage | 110V/ 120V/ 220V/ 230V/ 240V AC | |||||
Frequency | 50Hz/ 60Hz±5% (Auto) | ||||||
Waveform | Pure sine wave | ||||||
Transfer efficiency | ≥85% (full load) | ||||||
Waveform distortion factor | ≤3% | ||||||
Output power load factor | ≤0.8 | ||||||
Protection | Overload capacity | 105-120% at 30s; 120-150% at 10s; >150% at 5s | |||||
Low voltage | DC 10.5 (12V)/ DC 21 (24V)/ DC 42 (48V)/ DC 84 (96V), Alarm and shut down | ||||||
High temperature | 85℃, Auto shut down after alarm | ||||||
Short-circuit | Automatic shut-down | ||||||
Overvoltage | DC 17V (12V)/ DC 33V (24V)/ DC 66V (48V)/ DC 128V (96V), Auto shut down after alarm | ||||||
Grid charge | Charging Mode | PV+AC, 0-30A adjustable current (It’s the current range for charging the battery under (AC) commercial power preferred mode) | |||||
Function | Setting | Time & date setting, Contrast, Brightness, Sound, Voltage switch, Grid charger, Clear records, Reset | |||||
Work mode | Grid fist/ battery first/ standby mode | ||||||
LCD display | Record (fault record), system information | ||||||
Others | Switch time | ≤4ms | |||||
Cooling method | Fan | ||||||
Noise | <60 dBA | ||||||
Protection grade | IP30 | ||||||
Working temperature | -10~50℃ | ||||||
Environment humidity | 10%~90% (No condensation) | ||||||
Working elevation | <3000 (>1000m, derating) | ||||||
Certificate | CE, RoHS | ||||||
Warranty period | 12 months |